QUÍ KHÁCH CÓ NHU CẦU VUI LÒNG LIÊN HỆ:
HOTLINE: 0916551124
MAIL: ngocduyen.ans@ansvietnam.com
Web: tudonghoaans.com
ANS xin hân hạnh giới thiệu đến quí khách những sản phẩm mà chúng tôi là đại lý phân phối chính thức:
Vaisala Vietnam | Dewpoint Transmitter DMT143 L1C1X1A5AAASX |
Mechanical connection: ISO G½" Probe with DRYCAP180M Sensor (DMT242 Replacement); Digital interface: RS485 output | |
Analog signal output 4...20Ma | |
Analog output scale: Analog output scaling -80...+20 C Td | |
Alarm LED setpoint: Alarm LED setpoint other value | |
Process gas: Process gas air | |
Pressure Setting for Optimized Accuracy 1 bar | |
Cable 10.0 m (32.8 ft) | |
Sensor protection: Standard sintered filter | |
Accessories: DMT242 to DMT143 cable adapter | |
Standard package for DMT143; Vaisala identity | |
User guide language: Multilingual guide | |
Vaisala Vietnam | Hand-held humidity and Temperature meter HM70 F0B1A0EB |
Indicator with All Plugs to AC-Adapter | |
No Indicator accessories; Probe type: HMP76 | |
Calibration Certificate At Room Temperature | |
No Probe accessories; No Transmitter connection cable | |
Carrying case :weather proof carrying case for MI70 and long probe (HMP76/76B) (MI70CASE4); English User´s Guide HM70 | |
Vaisala Vietnam | Code: HM46 |
Hand-Held Humidity and Temperature Meter with HM46PROBE | |
Vaisala Vietnam | Code: HM42 |
Hand-Held Humidity and Temperature Meter with HM42PROBE | |
Vaisala Vietnam | Model: DM70 F5B1A3B1 |
Hand-held Dewpoint Meter | |
Indicator with All Plugs to AC-Adapter | |
Indicator Accessories: MI70LINK Interface sw, USB Cable | |
Probe Type: Dewpoint probe for the MI70 indicator, low Td's | |
Probe Accessories: Sampling Cell (DSC74) | |
No Connection Cable to a Transmitter | |
Carrying Case: Weatherproof case (hard plastic) MI70CASE3 | |
English User´s Guide DM70 | |
Vaisala Vietnam | Correct code: HMT330 3E0A021XBAC100A01AACAA1 |
Humidity and Temperature Transmitter; Transmitter type: HMT333 for general use; Probe cables: 2M; No additional Temperature Probe; Calculations: Code RH+T, No Display | |
Power supply: Universal AC-Power (100...240VAC) | |
Signal output: Analog Output 4...20mA | |
Analog output signals for Ch1: Temperature Range -40...+80C | |
Analog output signals for Ch2: 0...100%RH | |
No Analog output signals for Ch3; Output units: Metric Units | |
No Option for module slot 1, slot 2 | |
Cable bushings: Sealed Cable Gland M20x1.5 | |
No Transmitter installation | |
Humidity sensor: General purpose HUMICAP180 | |
Sensor protection: PPS Grid with Steel Netting | |
No Installation kit for probe; User´s Guide HMT330 German | |
No PC Accessories ;No Calibration Contract ISO9001 Calibration | |
Vaisala Vietnam | Humidity and Temperature Transmitter |
Correct code: HMT330 3E0A021BCAG100A01AACAA1 | |
Transmitter type: HMT333 for general use | |
Probe cables: 2m ; No Additional temperature probe, No Display | |
Calculations: Code RH+T ; Power supply: Universal AC-Power (100...240VAC) ; Signal output: Analog Output 4...20mA | |
Analog output signals for Ch1: RH (0...100%RH) | |
Analog output signals for Ch2: Temperature Range -20...+80C | |
No Analog output signals for Ch3; Output units: Metric Units | |
No Option for module slot 1 &2; Cable bushings: Sealed Cable Gland M20x1.5; No Transmitter installation | |
Humidity sensor: General purpose HUMICAP180 | |
Sensor protection: PPS Grid with Steel Netting | |
No Installation kit for probe; User´s Guide HMT330 German | |
No PC Accessories | |
No Calibration Contract ISO9001 Calibration | |
Vaisala Vietnam | Oil Moisture And Temperature transmitter |
Code: MMT162-C1DBB0AA60A1X | |
Transmitter Type: Pre product MMT162 MP300 Metal NPT + L2 | |
Measurement Parameter: Code aw+T | |
Analog Output, RS485 as Standard: RS485+ Analog Output CH1 4...20mA CH2 4...20m | |
Analog Output Parameter or Function for CH1: aw (0...1) | |
Analog Output Parameter or Function for CH2: aw (0...1) | |
Output Units: Metric Units | |
Sensor Protection: Stainless Steel Filter Standard | |
Cable for Aout and Power Supply (Port1): 2 m (9.8 ft) shielded threaded connector 90° | |
No Cable for RS485 and Power Supply (Port2) | |
Labeling: Vaisala; Quick Reference Guide MMT162 | |
Vaisala Vietnam | Item no: 222507 |
NPT1/2" plug | |
Vaisala Vietnam | Item no: 221494SP |
Stainless steel filter for high flow (for MMT162) | |
Vaisala Vietnam | Item no: 231520SP |
3 m Shielded PUR cable with 90° connector (for DPT145) | |
Vaisala Vietnam | Hand-held humidity and Temperature meter |
Code: HM70 D4D1A0AB | |
Indicator type: Indicator with Us AC-Adapter | |
Indicator accessories: MI70LINK software with USB cable (219687) | |
Probe type: HMP77; Calibration Certificate At Room Temperature | |
No Probe accessories ; No Transmitter connection cable | |
No Carrying case; English User´s Guide HM70 | |
Vaisala Vietnam | Code: HM70 F4C1B0EB |
Hand-held humidity and Temperature meter | |
Indicator type: Indicator with All Plugs to AC-Adapter | |
Indicator accessories: MI70LINK software with USB cable (219687) | |
Probe type: HMP76B (chemical purge and sensor preheating) | |
Calibration Certificate At Room Temperature | |
Probe accessories: Probe Holder for HMP76/76B | |
No Transmitter connection cable | |
Carrying case: weather proof carrying case for MI70 and long probe (HMP76/76B) (MI70CASE4); English User´s Guide HM70 |
Hãy liên hệ với chúng tôi để được hỗ trợ giá tốt nhất!!!
Hot line: 0916551124 (@ Duyên)
[E]: ngocduyen.ans@ansvietnam.com
Sky: duyen_ans
Website: tudonghoaans.com
ANS VIETNAM là một trong những Công ty hàng đầu
chuyên cung cấp máy móc, thiết bị cho ngành công nghiệp, điện
công nghiệp và điều khiển tự động của các hãng nổi tiếng :Celduc Vietnam, sterilair vietnam, Vaisala Vietnam, Balluff Vietnam, Metrix Vietnam, Kofloc Vietnam, Meister Vietnam, AGR Vietnam, Electro Sensor
Vietnam, Mts Sensor Vietnam, Hans Schmidt
Vietnam, FMS Vietnam, IMO Vietnam, Sanko Denshi
Vietnam, Takuwa Vietnam, Towa Seiden Vietnam, PCB Vietnam,…
#HM70 #maydocamtay #vaisala #vaisalavietnam #đạilý #mmt162
Không có nhận xét nào:
Đăng nhận xét